There are differential end connection for control valve end connection , such as flange connection, threaded, or even welded end. Flange connection is the most common control valve end connection in the oil & gas application. Other connection such as threaded or welded end is only used in particular application.
The type of control valve end connection shall refer to any project specification or a piping class data sheet. In general , if valve size is over 2”, it shall have a flange connection, threaded connection is acceptable for 2” and below. Welded end control valve connection is rarely used except for an application that requires no leakage in the connection between valve and pipe line or any pipe stress consideration.
The connection between flange and valve body are preferably used an integral body flange casting. It means the control valve body and a flange, casting together so that there is no welding requirement to joint the valve and the flange.
In case the sleeve control valve factory couldn’t have an integral body flange casting, as a rule of thumb used a weld neck flange that require a butt weld or full penetration weld to connect flange and valve body. Later on, this weld will require a NDE (Non Destructive Examination) Radiographic Test.
Slip on flange that use a fillet weld shall not be used because fillet weld is weaker than butt welded. Socket weld flange that use fillet weld may be used for valve 1 ½ inch and below. Even though socket weld flange also use fillet weld, but the internal weld of this flange increase the fatigue strength more than the slip on flange.
This flange is allowable for small size of control valve end connection due to difficulties of but weld perform in such size. All fillet weld connection will require a Magnetic Particle Examination or Liquid Penetrant Test.
There are three types of flange facing that will be used in the valve end connection as follow:
1. Flat Face Flange (FF Flange) :
These are used for low pressure or low valve class such as class 150 for control valve
2. Raised Face Flange (RF Flange) :
These are used for control valve class such as class 300 and class 600.
3. Ring Type Join Flange (RTJ Flange) :
These are used for high class such as class 900 and above.
- Kentintrol valve
- Tuenkers automation
- Festo valves and drives
- Testo digital multimeter
- E+H analytics, flow measurement, level, pressure and more
- VEGA level meter
- servo valve for gas turbine G771K201A for power station
- Charging Dome Valve For Fly Ash Handing System
- Valve D661-4043 for power generation
- accumulator air inlet valve QXF-5 for power station
- Hydraulic reversing valve MG00.11.19.01 for thermal power plant
- solenoid valve 22FDA-F5T-W110R-20/LP power plant spare parts
- servo valve SV4-20(15)57-80/40-10-S451 for power generation
- AST solenoid valve coil Z6206052 for power station
- Isolation valve F3DG5S2-062A-220AC-50-DFZK-V/B08 for thermal power plant
- Fluorine lined lift check valve
- bellows globe valve KHWJ25F-1.6P for power station
- Shutoff valve F3RG03D330 for power plant
- servo valve SM4-40(40)151-80/40-10-H919H power plant spare parts
- pressure relief valve DBDS10GM10/5 for power generation
- solenoid valve DG4V 3 0A M U D6 60 for power station
- bellows globe valve (welded) WJ25F1.6P for power plant
- AST/OPC solenoid valve coil 300AA00086A for power generation
- globe valve SHV6.4 for power station